Elro HIS20S Security & home automation system EXPAN Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sicherheit Elro HIS20S Security & home automation system EXPAN herunter. ELRO HIS20S Security & home automation system EXPANDED USERS MANUAL User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Home Integrated System

Home Integrated System Wireless Security & Home Automation System Instal

Seite 2 - CONTENTS

8 Inside View of Smart Home Box TESTING THE SMART HOME BOX & REMOTE CONTROL 1. Press ,

Seite 3 - KIT CONTENTS

9 The PIR Detector adopts a 1/2 AA size 3.6V Lithium battery which under normal conditions will have typical life in excess of 4 years. When the ba

Seite 4 - INTRODUCTION AND OVERVIEW

10 2. Carefully drill out the required mounting holes in the rear cover using 3mm drill according to whether the unit is being mounted in a corner or

Seite 5

11 Set the required sensitivity detection using DIP2 of SW2 as follows: ON high sensitivity detection OFF low sensitivity detection Note: The h

Seite 6

12 1. Press , , to put the system into Test mode. ‘WALK TEST’ will be displayed. 2. Press to activate Walk

Seite 7 - WIREFREE ALARM SYSTEM

13 2. Fit the 3.6V Lithium battery supplied, with the negative (-) towards the battery spring. 3. Mount the Detector to the fix

Seite 8 - SMART HOME BOX

14 b. Select ‘3-1 Wireless Sensor Zone’ and press . c. ‘Input (01-32) Sensor Zone’ and press . d. An indication of ‘:1 Learning ID’

Seite 9 - MOUNTING THE SMART HOME BOX

15 status of the plug-in light fixtures or home appliances without controlling via Smart Home Box. LEARNING ID CODE In order to communicate with the

Seite 10 - PASSIVE INFRARED DETECTORS

16 1. Press , , to put the system into Test mode. ‘WALK TEST’ will be displayed. 2. Press to activate Walk Te

Seite 11 - INSTALLING THE PIR DETECTORS

17 TESTING THE SYSTEM INITIAL TESTING As the system is initially installed it is recommended that each device is tested in turn as it is installed, (

Seite 12 - SETTING THE PIR DETECTORS

CONTENTS KIT CONTENTS 1 INTRODUCTION AND OVERVIEW 2 Multiple Users 2 System Arming 2 Zones 2 Entry/Exit De

Seite 13 - TESTING THE PIR DETECTORS

18 Press to exit Walk Test and return to the top level Test Mode menu. RF ENVIRONMENT TEST Scroll through the top level Test Mode menu until ‘

Seite 14 - DETECTOR(S)

19 Night Alarm ON Key Tone ON Back Light 20s Error Beep 30s Auto Report Function 12h RF Jamming Detection OFF Alarm Relay On Until Disarm Zone

Seite 15 - SETTING THE MAGNETIC CONTACT

20 Backup & Restore Backup Today’s DD/MM/YY Restore Not Programmed RESET After carrying out the following steps, the Smart Home Box will not r

Seite 16 - ON/OFF RECEIVER

21 PROGRAMMING INSTRUCTIONS With the system in Disarm Mode. Press , , Admin Password The system is no

Seite 17 - WALL SWITCH

22 display once the system is armed/disarmed by the particular user. The maximum memorized capacity for each user name is 15 digits. Scroll through t

Seite 18 - EXTERNAL CONNECTIONS

Code Learning Pressing , or button on the remote control will enable the Smart Home Box to learn the ID code. Scroll through the menu un

Seite 19 - TESTING THE SYSTEM

24 HOME BOX SETUP 2. Home Box Setup PROGRAM MODE Code:2-10 Zone Lockxxx

Seite 20 - DEFAULT SETTINGS

25 Scroll through the top level programming menu until ‘2. HOME BOX SETUP’ is displayed and press . Note: After completing the system setup pre

Seite 21 - GSM Gateway SMS Remote

26 KEY TONE This feature, if enabled, allows the Smart Home Box to sound a tone each time the keypad is pressed. Default setting: ON Scroll through

Seite 22

27 ALARM RELAY This setting controls the operation period for the NO/NC hardwired output relay contacts following an alarm condition being initiated.

Seite 23 - PROGRAMMING INSTRUCTIONS

1 KIT CONTENTS The Alarm System should contain the following components. For HIS20S 1 x Smart Home Box 1 x Wireless Key 1 x PIR Detector 1 x Remote

Seite 24

28 Press to enable the Entry-delay beep, or Press to disable the Entry-delay beep. DATE This feature is for setting of local date. De

Seite 25

29 SECURITY SENSOR ZONE SETUP (for Wire Sensor Zone) (for Wireless Sensor Zone) :6 Night Arm

Seite 26

30 This section is for setting of adding and categorizing of security devices (e.g. PIR detector). Scroll through the programming menu until ‘3. SECU

Seite 27

31 - used to provide 24-hour monitoring of any Fire/Smoke detectors fitted to the system. Activation of any detector will immediately initiate a Full

Seite 28

32 Press to disable the Magnetic Contact Detector. AUTO REPORT This feature, if enabled, allows the detector to give feedback to the Smart Home B

Seite 29

33 PHONE/LINE SETUP PROGRAM MODECode: 4-4 Dial Method Setup: xxxxDTMFPULSE4-1 Voice DialSetup 4. Phone/L

Seite 30

34 Scroll through the programming menu until ‘4-1. Voice Dial Setup’ is displayed and press . Note: After completing the Phone/Line Setup press

Seite 31 - (for Wireless Sensor Zone)

35 Press to delete the character under the cursor. Press and hold to erase the entire phone number. UNIT ID NUMBER This helps central

Seite 32

36 Note: If you find Monitor Center is not working properly, please check the telephone no. and Unit ID no. you enter are co

Seite 33

37 NUMBER OF DIALING CALL This facility controls the number of dialing call via the connected telephone line. Default setting: one call Scroll thr

Seite 34

2 INTRODUCTION AND OVERVIEW MULTIPLE USERS The system allows for up to 7 Users and an Administrator to be configured. This allows the system Event L

Seite 35 - PHONE/LINE SETUP

38 NOTIFICATION SETUP PROGRAM MODECode: 5. Notification Setup 5-1 Set TEL No. Input Number Delete In

Seite 36

39 NOTIFICATION SETUP Scroll through the programming menu until ‘5. Notification Setup’ is displayed and press . Note: After completing the Notif

Seite 37

40 Enter the required number (1-6). Press to save and exit, or Press to exit without saving. DIAL ROUND This sets the maximum number o

Seite 38

41 GREEN HOME SETUP PROGRAM MODE Code: 6. Green Home6-1 Green Control 6-2 Green Remote/Sensor Input

Seite 39

42 Green Home setting is designed specially for home automation types of devices, i.e. device with 433 MHz radio frequency. Scroll through the top lev

Seite 40 - NOTIFICATION SETUP

43 Scroll through available options, (Curtain Switch, Dimmer and Switch Device ) until the required model type is displayed and then Press to s

Seite 41

44 Press to retain the device. RECORD SCENE VOICE This voice record is set for scene, event and schedule. Scroll through the menu until ‘6-3

Seite 42

45 ENHANCE SETUP PROGRAM MODE Code:7. Enhance7-1 Enhance Device Input (01-12) E Device NO. :1 Model T

Seite 43 - GREEN HOME SETUP

46 Enhance setting is designed specially for transceiver type of devices, i.e. device with 868 MHz radio frequency. Scroll through the top level pr

Seite 44

47 BACKUP & RESTORE Scroll through the programming menu until ‘8. BACKUP & RESTORE’ is displayed and press . Use the

Seite 45

3 QUICK SET The system may be fully armed in 5 seconds using the quick set facility, overriding the programmed exit-delay. This is useful for setting

Seite 46

48 OPERATING INSTRUCTIONS When leaving the premises, the system must be Armed. However, before doing so, check that all windows are closed and lock

Seite 47 - ENHANCE SETUP

49 Password, and then the ‘Enter’ button. If User password is correct, an indication of ‘Night Arm’ will be shown on the LCD screen:

Seite 48

50 Use (On), (Off), (Start) and (Stop) buttons to control the green control related actions. Scene Press to enter scene selectio

Seite 49 - BACKUP & RESTORE

51 Setting Sequence: Press -> plays “I will watch over the house!” -> system enters fully arm mode -> PIR Detector sets to ON while Ma

Seite 50 - OPERATING INSTRUCTIONS

52 Press to initiate ARM. Press to initiate Partial Arm. Press to initiate Holiday Arm. Press to D

Seite 51

53 removed). Wall Switch Under low battery conditions, when the button is pressed, the LED will flash. Under normal battery conditions the LED will

Seite 52 - On steadily Flash Off

54ALARM RECORD Complete the following information during installation for future reference when adding to your system and to assist Trouble Shooting.

Seite 53

55 Zone Detector Type(s) Location Type Chime Night Arm Partial Arm 33 34 35 36 You may make a note of your User P

Seite 54 - BATTERY MONITORING

56 ALARM LEVEL To help you distinguish the difference among Level Panic, Level 1, Level 2 and Level 3, their definition read as follows: Level Pan

Seite 55 - MAINTENANCE

57Gateway will send SMS message, error beep will generate at regular intervals and this specific event will be recorded in the event log as well. Lev

Seite 56 - ALARM RECORD

4 a 5 minute interval, this will also generate a Full Alarm condition. The jamming detection features in the Smart Home Box and Solar Siren operate i

Seite 57

58 TROUBLESHOOTING Smart Home Box not working – Power LED OFF or flashing 1. Mains power failure – check if other electrical circuits are operable.

Seite 58 - ALARM LEVEL

59 LED on remote control not illuminating, or is dim when unit is operated 1. Ensure battery is connected with correct polarity2. Ensure battery con

Seite 60 - TROUBLESHOOTING

5 PLANNING AND EXTENDING YOUR WIREFREE ALARM SYSTEM The following example shows a typical property incorporating the suggested positions for the Smar

Seite 61 - PROTOCOL

6 REMOTE CONTROL UNIT A LED indicator F Key Chain Ring B Fully Arm/Holiday Arm G Battery Cover C Night Arm/Partial Arm H Negative

Seite 62

7 connecting to a telephone master or secondary outlet. 7. Do not locate the Smart Home Box closer than 1m to any large metallic object, (e.g. mirro